Loading page content…
Loading page content…
Loading contract search results…
Loading contract details…
| Source: | Find a Tender Service (FTS) |
| Notice Type: | Tender notice |
| Buyer: | Northern Housing Consortium Ltd |
| Main Category: |
| Services |
| Procurement Method: | Open procedure |
| Tender Status: | Closed |
| Estimated Value (ex. VAT): | £575,000,000 |
| Estimated Value (inc. VAT): | £690,981,600 |
| Release Date: | 31 July 2025 |
| Application Deadline: | 15 September 2025 |
| Procurement ID (OCID): | ocds-h6vhtk-056a88 |
| Notice Reference: | 044885-2025 |
All 3 notices for this procurement, oldest first.
Active Fire Framework 2025
Active Fire Framework 2025
Active Fire Framework 2025
View Original Notice
Access the full notice on the official portal
| Call-off method: | Both: direct call-off and mini-competition |
| Maximum operators: | 220 |
The scope of this Framework Agreement is for the provision of active fire products and services. The Framework will cover, but is not limited to: •Risk assessments; inspections; fire equipment testing; and portable appliances testing •Fire products including fire detectors; manual and automatic action products; and fire-retardant products •Servicing and maintenance; fire safety and remedial works; security and access systems; emergency lighting; fire damper and fire collar maintenance; and minor works and servicing. The products and services shall fall into 4 separate Framework “LOTs”, further broken down into Sub-Lots, to reflect the structure of the industries. Supply Partners are invited to apply for one or more LOT(s) if applicable. LOT 1: Fire Products- Supply and Installation Sub-Lot 1.1 Fire Detection Sub-Lot 1.2 Smoke Control Systems Sub-Lot 1.3 Sprinkler System Sub-Lot 1.4 Misting System Sub-Lot 1.5 Fire Extinguisher Sub-Lot 1.6 Emergency Lighting Sub-Lot 1.7 Fire Alarm Monitoring Sub-Lot 1.8 Fire Escape Products Sub- Lot 1.9 Defibrillators LOT 2: Consultancy Sub-Lot 2.1 Fire Risk Assessments Sub-Lot 2.2 Fire Risk Inspections Sub-Lot 2.3 Fire Engineering LOT 3: Servicing Sub-Lot 3.1 Fire Servicing and Maintenance Sub-Lot 3.2 Fire Safety, Minor and Remedial Works Sub-Lot 3.3 Emergency Lighting Maintenance Sub-Lot 3.4 Fire Damper and Fire Collar Maintenance Sub-Lot 3.5 Fire Extinguisher Maintenance Sub-Lot 3.6 Maintenance of Defibrillators Sub-Lot 3.7 Fire Escape Products Maintenance Sub-Lot 3.8 Sprinkler Systems Service and Maintenance Sub-Lot 3.9 Misting System Service and Maintenance LOT 4: Fully Managed Service To view this notice, please click here: https://www.delta-esourcing.com/delta/viewNotice.html?noticeId=969251536
Design, installation, commissioning and maintenance of fire detection systems to ensure the safety and compliance of buildings and facilities. The goal is to provide early detection of fire incidents to protect life and property. Purpose The purpose of the fire detection system is to: •Detect fire incidents at the earliest possible stage. •Alert occupants and emergency services promptly. •Facilitate safe evacuation and firefighting efforts. •Ensure compliance with relevant fire safety regulations and standards.
Supply and installation of smoke control systems to ensure the safety and compliance of buildings and facilities. The goal is to provide effective smoke control to facilitate safe evacuation and fire suppression efforts. Purpose The purpose of this specification is to: •Supply high-quality manual and automatic smoke control products. •Ensure proper installation and functionality of these products. •Comply with relevant fire safety regulations and standards.
The requirements for the design, supply, installation, testing, and commissioning of sprinkler systems to ensure fire protection for the specified premises. The purpose of this specification is to: •Supply high-quality sprinkler systems to suppress or extinguish fire to protect life and property •Ensure proper installation and functionality of these products. •Comply with relevant fire safety regulations and standards.
Design, supply, installation, testing, and commissioning of misting systems to ensure fire protection for the specified premises. The purpose is to: •Supply high-quality misting systems to suppress or extinguish fire to protect life and property •Ensure proper installation and functionality of these products. •Comply with relevant fire safety regulations and standards.
The requirements for the supply of fire extinguishers to ensure adequate fire protection for the specified premises.
The requirements for the design, supply, installation, testing, and commissioning of emergency lighting systems to ensure safe evacuation during power outages or emergencies.
The requirements for the supply, installation, testing, and commissioning of a fire alarm monitoring system to ensure continuous surveillance and prompt response to fire incidents.
The supply, installation, testing, and commissioning of fire escape products to ensure safe evacuation during emergencies.
The supply of defibrillators to ensure their proper operation and availability in case of cardiac emergencies.
The requirements for conducting Fire Risk Assessments (FRA) to ensure the safety and compliance of buildings and facilities. The goal is to identify potential fire hazards, evaluate risks, and implement measures to mitigate these risks. The requirements of an FRA are to ensure that it assists member organisations to meet their obligations under the Regulatory Reform (Fire Safety) Order 2005. The purpose of the FRA is to: •Identify fire hazards and risks within the premises. •Evaluate the effectiveness of existing fire safety measures. •Recommend improvements to enhance fire safety. •Ensure compliance with relevant fire safety regulations and standards
The requirements for conducting Fire Risk Inspections (FRI) to ensure the safety and compliance of buildings and facilities. The goal is to identify potential fire hazards, evaluate risks, and implement measures to mitigate these risks. The purpose of the FRI is to: •Physically inspect buildings to identify fire hazards and risks within the premises or to evaluate the risk relating to specific incidents, changes to buildings or building design. •Evaluate the effectiveness of existing fire safety measures. •Recommend improvements to enhance fire safety. •Ensure compliance with relevant fire safety regulations and standards.
The requirements for Active Fire Engineering (AFE) to ensure the safety and compliance of buildings and facilities. The goal is to design, implement, and maintain effective fire protection systems. Purpose The purpose of the AFE is to: •Provide advice and guidance on areas of complex fire safety •Design fire protection systems that prevent, detect, and respond to fires aligned to the advice. •Ensure the effectiveness of fire safety measures. •Comply with relevant fire safety regulations and standards.
The requirements for the servicing and maintenance of fire protection systems to ensure their proper operation and compliance with safety standards.
The requirements for fire safety and remedial works to ensure compliance with fire safety regulations and enhance the overall safety of the premises
The requirements for the maintenance of emergency lighting systems to ensure safe evacuation during power outages or emergencies.
The requirements for the maintenance of fire dampers and fire collars to ensure their proper operation and compliance with fire safety standards.
Outlines the requirements for maintenance and servicing of fire extinguishers to assist the suppression of fire in the event of an emergency.
Outlines the requirements for the maintenance of defibrillators to ensure their proper operation and availability in case of cardiac emergencies
Outlines the requirements for the maintenance of fire escape products to ensure safe evacuation during emergencies.
Outlines the procedures for the regular service and maintenance of sprinkler systems to ensure optimal performance and compliance with safety standards
Outlines the procedures for the regular service and maintenance of misting systems to ensure optimal performance and compliance with safety standards.
Must be able to undertake ALL activities detailed within those LOTs/Sub-Lots either directly or through carefully selected sub-contractors or consortia arrangements
Document pack· 1 file
Published contracts in the last 12 months
12
total contracts
£2285.0m
total value
£326,428,571
average contract size
Typical categories
Furniture Services Framework 27-31
Northern Housing Consortium Ltd · WAC-593889
Property Security and Electrical Works Framework 27-31
Northern Housing Consortium Ltd · WAC-593893
Sustainable Energy and Resilience Products Framework 2026
Northern Housing Consortium Ltd · WAC-593982
Pipeline status
Not addedImports the contract into your BidWriter pipeline · Qualify before you commit to bid
Application Deadline
15 September 2025
Closed
Estimated Value
£575,000,000
Need help writing this bid?
Our specialists write winning tender responses. Free consultation, no obligation.
Book a free consultation →