The services required by the contract both within occupied properties, void properties and communal areas, include but are not restricted to:- Routine maintenance and regular testing / inspection of all electrical installations (EICRs), emergency lighting, security systems (CCTV, door entry, etc), communal TV aerial systems, portable appliance testing and mechanical ventilation systems (including air conditioning), and lightning protection systems- Electrical day to day responsive repairs and full electrical rewires
The services required by the contract both within occupied properties, void properties and communal areas, include but are not restricted to:
- Routine maintenance and regular testing / inspection of all electrical installations (EICRs), emergency lighting, security systems (CCTV, door entry, etc), communal TV aerial systems, portable appliance testing and mechanical ventilation systems (including air conditioning), and lightning protection systems
- Electrical day to day responsive repairs and full electrical rewires
The work comprises the complete demolition of the existing retaining wall to the
rear of the existing tenement properties at 13-37 St. Monance Street, Glasgow and includes the breaking
out and removal of all sub-structures and foundations, the construction of a new retaining wall, and the
making good of all disturbed ground and landscaping, etc. on completion of works.
ng homes wishes to appoint up to three contractors to the Framework Agreement for undertaking ad-hoc stonework repairs to traditional sandstone properties as may be required from time to time over the course of the Framework.
Golding Homes requires a suitable contractor to complete regeneration building works to our Cambridge Crescent Estate in line with our tender documents
Golding Homes requires a suitable contractor to complete regeneration building works to our Cambridge Crescent Estate in line with our tender documents
Electrical Inspection and Condition Report in communal and domestic properties, as well as any other Golding Homes owned address including commercial units and office.
Installation of LD2 system with domestic addresses, which include Aico Ei3028 (heat/co) in kitchen regardless of gas, Ei3024 (multi sensor fire alarm) in hallways and lounges, Ei3018 in rooms with gas boilers/appliances. All detection is to be interlinked with Ei3000MRF modules and Ei450 radio LINK alarm controller and on request Ei1000G for remote monitoring.
In the event there is already an LD2 system in situ, the system should only be renewed if detection expires within two years.
Golding Homes will require the next replacement date for all detection within the property to be provided monthly on jobs completed in excel format
Golding Homes will only accept satisfactory EICR, therefore all Cat1 and cat 2 must be completed at the time of inspection, if not make a mutually agreeable appointment with the customer to rectify
Under no circumstances must a property be left with a category 1 fault
Assisting the clients DSO with emergencies from time to time should the need arise, this will include repairs/replacements.